Files
ashvale-station/scripts/simulate.py
T
kemal e27a4b41c8 Outlook to Live, humidity calibration, Models tab rebuilt without scrollers
Seven day outlook moves from History to Live, which now runs four rows.
Conditions ahead tightened so the Live column no longer needs a scroller.

Adds HumidityCompensator: an additive RH offset estimated by one-step RLS from
a trusted hygrometer, clamped to +/-35%, persisted, exposed at
POST /api/calibrate/humidity and on the renamed Models and calibration tab.

It also implements the psychrometric term (RH moved from element temperature
onto air temperature via conserved vapour pressure) but leaves it OFF by
default. The thermal argument predicts a hot element reads low; measured
against a reference hygrometer this board read 75.4% where the truth was
50.4%, so it reads HIGH and that correction would push it the wrong way. When
the flag is enabled, simulate.py applies the exact inverse, per the
simulator/compensator trap in DESIGN.md section 2.

Models pane rebuilt: the scorecard is one column per target so all 18 heads
are visible, and no panel on the tab uses an internal scroller. Verified in
Chromium at 1600x900: Live, History and Models all report zero scrollbars,
zero clipping, no page scroll, zero console errors. Backtest is numerically
identical to the previous commit, confirming the humidity work is a no-op
while the flag is off.
2026-08-15 21:36:10 +01:00

230 lines
9.8 KiB
Python

#!/usr/bin/env python3
# Copyright 2026 Kemal Yaylali
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
"""Seed the database with synthetic history.
Why this exists: a freshly flashed Pi has no history, and a forecaster
with no history is a random number generator with a nice dashboard. This
script writes physically plausible past telemetry so you can exercise
training, verification and the whole dashboard before the real station
has logged its first night.
The generator is not a toy. It is a three-component stochastic model:
pressure Ornstein-Uhlenbeck, tau = 30 h, sigma = 9 hPa
(roughly the observed synoptic variability of NW Europe)
temperature seasonal harmonic + solar-driven diurnal cycle
+ OU anomaly (tau = 6 h), with a nocturnal inversion term
humidity driven inversely by temperature about a dew point that
itself performs a slow random walk, which is what makes
RH and T correlate the way they actually do
Everything is then pushed through the same CPU-heating and noise model
the real sensor suffers from, so a model trained here does not fall over
when it meets real data.
python scripts/simulate.py --days 21 --wipe
"""
from __future__ import annotations
import argparse
import math
import sys
import time
from pathlib import Path
import numpy as np
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from ashvale.config import load_config # noqa: E402
from ashvale.estimation import SignalTracker # noqa: E402
from ashvale.physics import ( # noqa: E402
clear_sky_irradiance,
dew_point,
sea_level_pressure,
solar_position,
)
from ashvale.storage import Store # noqa: E402
def generate(days: float, step_s: int, lat: float, lon: float,
seed: int = 11, end: float | None = None,
psychrometric: bool = False) -> dict:
rng = np.random.default_rng(seed)
n = int(days * 86400 / step_s)
# Anchoring to wall clock makes a fixed seed insufficient for reproducibility:
# the OU realisation repeats, but the timestamps shift, which moves solar
# elevation, day of year and the seasonal harmonic. Those feed the temperature
# model directly, so two same-seed runs produce different data. Pin end as well
# and the backfill becomes bit-reproducible, which is what before/after
# evidence on a model change actually requires.
end = time.time() if end is None else end
ts = end - np.arange(n)[::-1] * step_s
# --- synoptic pressure: OU process
tau_p, sigma_p = 30 * 3600.0, 9.0
press = np.zeros(n)
a = math.exp(-step_s / tau_p)
noise_scale = sigma_p * math.sqrt(1 - a * a)
for i in range(1, n):
press[i] = a * press[i - 1] + noise_scale * rng.normal()
press_slp = 1013.0 + press
# --- solar forcing
elev, _ = solar_position(ts, lat, lon)
elev = np.atleast_1d(elev)
ghi = clear_sky_irradiance(elev)
cloud = np.clip(0.45 + 0.35 * np.sin(2 * np.pi * ts / (4.5 * 86400)) +
0.25 * rng.normal(size=n).cumsum() / math.sqrt(n), 0.0, 1.0)
lux = np.maximum(ghi * 45.0 * (1.0 - 0.85 * cloud), 0.0) + 6.0
# --- temperature: season + diurnal + OU anomaly + inversion at night
doy = np.array([time.gmtime(float(t)).tm_yday for t in ts])
seasonal = 6.5 * np.sin(2 * np.pi * (doy - 105) / 365.25)
diurnal = 0.011 * ghi * (1.0 - 0.6 * cloud)
inversion = -1.8 * (elev < -3).astype(float) * (1.0 - cloud)
tau_t, sigma_t = 6 * 3600.0, 1.9
at = math.exp(-step_s / tau_t)
anom = np.zeros(n)
for i in range(1, n):
anom[i] = at * anom[i - 1] + sigma_t * math.sqrt(1 - at * at) * rng.normal()
# pressure and temperature anomalies are correlated in the real world
anom += 0.12 * press
temp = 11.5 + seasonal + diurnal + inversion + anom
# --- humidity via a slowly wandering dew point
dew = temp - 4.5 + 2.5 * np.sin(2 * np.pi * ts / (3.2 * 86400))
dew -= 0.10 * press
dew = np.minimum(dew, temp - 0.2)
es_t = 6.112 * np.exp(17.625 * temp / (243.04 + temp))
es_d = 6.112 * np.exp(17.625 * dew / (243.04 + dew))
rh = np.clip(100.0 * es_d / es_t, 8.0, 100.0)
# CPU temperature: a slow AR(1) load process, not white noise. A Zero 2 W
# under a steady FastAPI load drifts by a degree or two over minutes, it
# does not jitter by four degrees between samples.
cpu_load = np.zeros(n)
a_cpu = math.exp(-step_s / (900.0))
for i in range(1, n):
cpu_load[i] = a_cpu * cpu_load[i - 1] + 1.6 * math.sqrt(1 - a_cpu * a_cpu) * rng.normal()
cpu = temp + 21.0 + cpu_load
# The sensor sits in a thermal gradient between the room and the SoC.
# The compensator inverts T = T_raw - k (T_cpu - T_raw), so the forward
# model must be its exact inverse: T_raw = (T + k T_cpu) / (1 + k).
# Generating it any other way bakes a bias into the synthetic data that
# no amount of calibration can remove, and quietly caps your skill score.
k_true = 0.55
temp_raw = (temp + k_true * cpu) / (1.0 + k_true) + 0.05 * rng.normal(size=n)
# If the compensator will move RH from the element temperature onto the air
# temperature, the forward model here must be its exact inverse, or the
# synthetic data bakes in a bias no calibration can remove. Same trap as the
# thermal algebra above. Off by default, matching sensor.hum_psychrometric.
if psychrometric:
es_raw = 6.112 * np.exp(17.625 * temp_raw / (243.04 + temp_raw))
rh_sensor = np.clip(rh * es_t / es_raw, 0.0, 100.0)
else:
rh_sensor = rh
press_station = press_slp / (1.0 + 0.0) - 1.8 # nominal 15 m offset
press_station += 0.05 * rng.normal(size=n)
return {
"ts": ts, "temp": temp, "temp_raw": temp_raw, "rh": rh_sensor + 0.4 * rng.normal(size=n),
"press": press_station, "press_slp": press_slp, "cpu": cpu,
"lux": lux * (0.85 + 0.3 * rng.random(n)), "dew": dew, "cloud": cloud,
}
def main() -> None:
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("--days", type=float, default=14.0)
ap.add_argument("--step", type=int, default=300, help="seconds between rows")
ap.add_argument("--seed", type=int, default=11)
ap.add_argument("--end", type=float, default=None,
help="unix timestamp the history ends at; defaults to now. "
"Pin it with --seed for a bit-reproducible backfill")
ap.add_argument("--wipe", action="store_true", help="clear existing telemetry first")
ap.add_argument("--config", default=None)
args = ap.parse_args()
cfg = load_config(args.config)
store = Store(cfg.storage.db_path)
# The Kalman process noise is tuned for the real sampling cadence (2 s).
# Backfilling at 300 s steps with the same q gives Q_level = q*dt^3/3, which
# is five orders of magnitude larger, so the filter abandons smoothing and
# tracks measurement noise. Its rate estimates then blow past anything
# physical and poison the all-time records. Scale q by (real_dt/step)^3 so
# the synthetic history has the same effective smoothing as the live station.
scale = (cfg.sensor.sample_period_s / float(args.step)) ** 3
cfg.sensor.kalman_q_temp *= scale
cfg.sensor.kalman_q_hum *= scale
cfg.sensor.kalman_q_press *= scale
if args.wipe:
with store._conn() as conn:
conn.execute("DELETE FROM telemetry")
conn.execute("DELETE FROM forecasts")
conn.execute("DELETE FROM scores")
print("cleared existing telemetry, forecasts and scores")
data = generate(args.days, args.step, cfg.site.latitude, cfg.site.longitude,
args.seed, args.end, cfg.sensor.hum_psychrometric)
tracker = SignalTracker(cfg)
n = data["ts"].size
t0 = time.time()
for i in range(n):
ts = float(data["ts"][i])
est = tracker.step(ts, float(data["temp_raw"][i]), float(data["rh"][i]),
float(data["press"][i]), float(data["cpu"][i]))
slp = float(sea_level_pressure(est["press_smooth"], est["temp_smooth"],
cfg.site.altitude_m))
store.insert_telemetry({
"ts": ts,
"temp_raw": data["temp_raw"][i],
"temp_c": est["temp_c"],
"temp_smooth": est["temp_smooth"],
"temp_rate": est["temp_rate"],
"hum": data["rh"][i],
"hum_smooth": est["hum_smooth"],
"press": data["press"][i],
"press_slp": slp,
"press_smooth": est["press_smooth"],
"press_rate": est["press_rate"],
"cpu_temp": data["cpu"][i],
"dew_c": float(dew_point(est["temp_smooth"], est["hum_smooth"])),
"lux": data["lux"][i],
"r": data["lux"][i] * 0.30, "g": data["lux"][i] * 0.34, "b": data["lux"][i] * 0.28,
"pitch": 0.0, "roll": 0.0, "yaw": 180.0, "compass": 180.0,
"ax": 0.0, "ay": 0.0, "az": 1.0, "gx": 0.0, "gy": 0.0, "gz": 0.0,
})
if i % 500 == 0:
print(f" {i}/{n} rows", end="\r", flush=True)
print(f"\nwrote {n} rows spanning {args.days:.1f} days in {time.time() - t0:.1f}s")
print(f"database: {cfg.storage.db_path}")
print("next: python scripts/evaluate.py (or just start the server)")
if __name__ == "__main__":